Türkçe
×
All rights reserved. All content and images used on our website are
owned by CNS Tank, and unauthorized use is subject to legal action.
İnviva
 || CNS Tank - Cryogenic Tank | Cryogenic Storage Tanks, Air Tanks, Crude Oil Storage Tank, Tank Container, LPG Storage Pressure Tanks, LPG Transport Tanks, Evaporators, Engineering, Technical Service & Spare Parts
 || CNS Tank - Cryogenic Tank | Cryogenic Storage Tanks, Air Tanks, Crude Oil Storage Tank, Tank Container, LPG Storage Pressure Tanks, LPG Transport Tanks, Evaporators, Engineering, Technical Service & Spare Parts
 || CNS Tank - Cryogenic Tank | Cryogenic Storage Tanks, Air Tanks, Crude Oil Storage Tank, Tank Container, LPG Storage Pressure Tanks, LPG Transport Tanks, Evaporators, Engineering, Technical Service & Spare Parts
 || CNS Tank - Cryogenic Tank | Cryogenic Storage Tanks, Air Tanks, Crude Oil Storage Tank, Tank Container, LPG Storage Pressure Tanks, LPG Transport Tanks, Evaporators, Engineering, Technical Service & Spare Parts

CNS Tank manufactures the following liquefied gas tanks:

Liquefied Natural Gas Tanks (LNG)
Liquid Nitrogen Tanks (LIN)
Liquid Oxygen Tanks (LOX)
Liquid Carbon Dioxide Tanks (LCO2)
Liquid Argon Tanks (LAR)
Liquefied Petroleum Gas - LPG

GENERAL FEATURES

Production and certification according to ADR, EN 13530, ASME (U STAMP), GOST standards.
Maximum transportation capacity within the legal limits and standards of each country.
Flexibility in production for various capacities according to customer demand.
Optional design conditions tailored to the region where the product will be used.
Vacuum and multi-layer super insulation.
Excellent ergonomic design for operation and service.
Stainless steel inner tank and pipes.
Design based on minimum operation time.
High-performance paint application compliant with EN 12944.
Non-destructive testing according to standards (Radiographic testing, Magnetic Particle Testing, Helium Testing, etc.).

LNG SEMI TRAILER
TYPE VOLUME LENGTH WIDTH HEIGHT
CON46SMT 46 m² 12957 mm 2550 mm 3780 mm
CON50SMT 50 m² 13940 mm 2550 mm 3780 mm
CON54SMT 54 m² 14940 mm 2550 mm 3780 mm

*Depending on the required operating pressure and the highway transportation capacities of countries, semi trailers compliant with standards can be manufactured.

Design Requirements: (LNG)
Design Code: EN 13530/ADR
Operating Pressure: 6 bar
Design Pressure: 7 bar
Test Pressure: 9.1 bar
Design Temperature: +50°C / -196°C
Inner Tank Material: Compliant with EN 10028-7
Outer Tank Material: Compliant with EN 10025-2
Radiographic Inspection: Compliant with EN 13530
Liquid Penetrant Test: Compliant with EN 13530
Insulation: Multilayer

LIN-LOX-LAR SEMI TRAILER
TYPE VOLUME LENGTH WIDTH HEIGHT
LAR CCL19SMT 19 m³ 10050 mm 2550 mm 3500 mm
LOX CCL24SMT 24 m³ 10550 mm 2550 mm 3500 mm
LIN CCL33SMT 33 m³ 10600 mm 2550 mm 3750 mm

*Depending on the required operating pressure and the highway transportation capacities of countries, semi trailers compliant with standards can be manufactured.

Design Specifications: (LIN-LOX-LAR)
Design Code: EN 13530/ADR
Operating Pressure: 3-16 bar
Design Pressure: 4-17 bar
Test Pressure: 5.2-22.1 bar
Design Temperature: +50°C / -196°C
Inner Tank Material: Compliant with EN 10028-7
Outer Tank Material: Compliant with EN 10025-2
Radiographic Testing: Compliant with EN 13530
Liquid Penetrant Testing: Compliant with EN 13530
Insulation: Multilayer

LPG SEMI TRAILER
TYPE VOLUME LENGTH WIDTH HEIGHT
COP47SMT 47 m³ 11500 mm 2550 mm 3750 mm
COP48SMT 48 m³ 11750 mm 2550 mm 3750 mm
COP57SMT 57 m³ 12250 mm 2550 mm 3750 mm

*Depending on the required operating pressure and the highway transportation capacities of countries, semi trailers compliant with standards can be manufactured.

GENERAL FEATURES

Production and certification are carried out according to ADR, EN 12493, ASME (U STAMP), and GOST standards.
Materials used for LPG transport tanks comply with certified standards such as EN 10028, ASME, etc., specified for 3.1-3.2.
High-performance painting is applied according to EN 12944.
Materials specified for LPG transport tanks are certified to comply with standards such as EN 10028, ASME, etc.
Maximum transport capacity is within existing legal limits and standards.
Production flexibility enables manufacturing tanks in different capacities based on customer demand.
Various piping configurations can be provided to meet customer needs.
Optional design conditions can be specified according to the region where the product will be used.
Excellent ergonomic design facilitates ease of operation and service.
Non-destructive testing methods such as Radiographic Testing, Liquid Penetrant Testing, Ultrasonic Testing, Magnetic Particle Testing, etc., are conducted in accordance with applicable standards.

Design Requirements: (LPG)
Design Code: EN 12493/ADR
Design Pressure: 15-26 bar
Design Temperature: -50°C / +70°C
Material: EN 10028-3
Radiographic Testing: EN 12493
Liquid Penetrant Testing: EN 12493